Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
3.
Acute Crit Care ; 39(1): 162-168, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38476069

RESUMEN

BACKGROUND: Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. METHODS: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. RESULTS: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. CONCLUSIONS: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.

4.
Front Med Technol ; 6: 1320810, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38333734

RESUMEN

The left ventricular outflow tract velocity time integral (LVOT VTI) is commonly used in the intensive care unit as a measure of stroke volume (SV) and how the SV changes in response to an intervention; therefore, the LVOT VTI is used to guide intravenous fluid management. Various peripheral Doppler surrogates are proposed to infer the LVOT VTI (e.g., measures from the common carotid artery). A recently-described, novel method of insonation has an excellent ability to detect change in the LVOT VTI. This approach raises important facets of Doppler flow and insonation error, as well as the general principles at play when using a peripheral artery to infer changes from the left ventricle. Relating the VTI of a peripheral artery to the LVOT VTI was recently described mathematically and may help clinicians think about the Doppler relationship between central and peripheral flow.

7.
J Intensive Care Med ; : 8850666231224396, 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38190576

RESUMEN

Background: The likelihood of a patient being preload responsive-a state where the cardiac output or stroke volume (SV) increases significantly in response to preload-depends on both cardiac filling and function. This relationship is described by the canonical Frank-Starling curve. Research Question: We hypothesize that a novel method for phenotyping hypoperfused patients (ie, the "Doppler Starling curve") using synchronously measured jugular venous Doppler as a marker of central venous pressure (CVP) and corrected flow time of the carotid artery (ccFT) as a surrogate for SV will refine the pretest probability of preload responsiveness/unresponsiveness. Study Design and Methods: We retrospectively analyzed a prospectively collected convenience sample of hypoperfused adult emergency department (ED) patients. Doppler measurements were obtained before and during a preload challenge using a wireless, wearable Doppler ultrasound system. Based on internal jugular and carotid artery Doppler surrogates of CVP and SV, respectively, we placed hemodynamic assessments into quadrants (Qx) prior to preload augmentation: low CVP with normal SV (Q1), high CVP and normal SV (Q2), low CVP and low SV (Q3) and high CVP and low SV (Q4). The proportion of preload responsive and unresponsive assessments in each quadrant was calculated based on the maximal change in ccFT (ccFTΔ) during either a passive leg raise or rapid fluid challenge. Results: We analyzed 41 patients (68 hemodynamic assessments) between February and April 2021. The prevalence of each phenotype was: 15 (22%) in Q1, 8 (12%) in Q2, 39 (57%) in Q3, and 6 (9%) in Q4. Preload unresponsiveness rates were: Q1, 20%; Q2, 50%; Q3, 33%, and Q4, 67%. Interpretation: Even fluid naïve ED patients with sonographic estimates of low CVP have high rates of fluid unresponsiveness, making dynamic testing valuable to prevent ineffective IVF administration.

9.
Diagnostics (Basel) ; 13(23)2023 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-38066832

RESUMEN

(1) Background: The inspiratory collapse of the inferior vena cava (IVC), a non-invasive surrogate for right atrial pressure, is often used to predict whether a patient will augment stroke volume (SV) in response to a preload challenge. There is a correlation between changing stroke volume (SV∆) and corrected flow time of the common carotid artery (ccFT∆). (2) Objective: We studied the relationship between IVC collapsibility and ccFT∆ in healthy volunteers during preload challenges. (3) Methods: A prospective, observational, pilot study in euvolemic, healthy volunteers with no cardiovascular history was undertaken in a local physiology lab. Using a tilt-table, we studied two degrees of preload augmentation from (a) supine to 30-degrees head-down and (b) fully-upright to 30-degrees head down. In the supine position, % of IVC collapse with respiration, sphericity index and portal vein pulsatility was calculated. The common carotid artery Doppler pulse was continuously captured using a wireless, wearable ultrasound system. (4) Results: Fourteen subjects were included. IVC % collapse with respiration ranged between 10% and 84% across all subjects. Preload responsiveness was defined as an increase in ccFT∆ of at least 7 milliseconds. A total of 79% (supine baseline) and 100% (head-up baseline) of subjects were preload-responsive. No supine venous measures (including IVC % collapse) were significantly related to ccFT∆. (5) Conclusions: From head-up baseline, 100% of healthy subjects were 'preload-responsive' as per the ccFT∆. Based on the 42% and 25% IVC collapse thresholds in the supine position, only 50% and 71% would have been labeled 'preload-responsive'.

10.
Crit Care Explor ; 5(12): e1022, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38094087

RESUMEN

Point of care ultrasound (POCUS) is a first-line tool to assess hemodynamically unstable patients, however, there is confusion surrounding intertwined concepts such as: "flow," "congestion," "fluid responsiveness (FR)," and "fluid tolerance." We argue that the Frank-Starling relationship is clarifying because it describes the interplay between "congestion" and "flow" on the x-axis and y-axis, respectively. Nevertheless, a single, simultaneous assessment of congestion and flow via POCUS remains a static approach. To expand this, we propose a two-step process. The first step is to place the patient on an ultrasonographic Diamond-Forrester plot. The second step is a dynamic assessment for FR (e.g., passive leg raise), which individualizes therapy across the arc of critical illness.

13.
Front Physiol ; 14: 1230654, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37614757

RESUMEN

While both cardiac output (Qcirculatory) and right atrial pressure (PRA) are important measures in the intensive care unit (ICU), they are outputs of the system and not determinants. That is to say, in a model of the circulation wherein venous return and cardiac function find equilibrium at an 'operating point' (OP, defined by the PRA on the x-axis and Qcirculatory on the y-axis) both the PRA and Qcirculatory are, necessarily, dependent variables. A simplified geometrical approximation of Guyton's model is put forth to illustrate that the independent variables of the system are: 1) the mean systemic filling pressure (PMSF), 2) the pressure within the pericardium (PPC), 3) cardiac function and 4) the resistance to venous return. Classifying independent and dependent variables is clinically-important for therapeutic control of the circulation. Recent investigations in patients with acute respiratory distress syndrome (ARDS) have illuminated how PMSF, cardiac function and the resistance to venous return change when placing a patient in prone. Moreover, the location of the OP at baseline and the intimate physiological link between the heart and the lungs also mediate how the PRA and Qcirculatory respond to prone position. Whereas turning a patient from supine to prone is the focus of this discussion, the principles described within the framework apply equally-well to other more common ICU interventions including, but not limited to, ventilator management, initiating vasoactive medications and providing intravenous fluids.

14.
Ultrasound J ; 15(1): 32, 2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37505318

RESUMEN

Providing intravenous (IV) fluids to a patient with signs or symptoms of hypoperfusion is common. However, evaluating the IV fluid 'dose-response' curve of the heart is elusive. Two patients were studied in the emergency department with a wireless, wearable Doppler ultrasound system. Change in the common carotid arterial and internal jugular Doppler spectrograms were simultaneously obtained as surrogates of left ventricular stroke volume (SV) and central venous pressure (CVP), respectively. Both patients initially had low CVP jugular venous Doppler spectrograms. With preload augmentation, only one patient had arterial Doppler measures indicative of significant SV augmentation (i.e., 'fluid responsive'). The other patient manifested diminishing arterial response, suggesting depressed SV (i.e., 'fluid unresponsive') with evidence of ventricular asynchrony. In this short communication, we describe how a wireless, wearable Doppler ultrasound simultaneously tracks surrogates of cardiac preload and output within a 'Doppler Starling curve' framework; implications for IV fluid dosing are discussed.

15.
Front Biosci (Elite Ed) ; 15(2): 12, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-37369572

RESUMEN

BACKGROUND: The change in the corrected flow time of the common carotid artery (ccFTΔ) has been used as a surrogate of changing stroke volume (SVΔ) in the critically-ill. Thus, this relatively easy-to-obtain Doppler measure may help clinicians better define the intended effect of intravenous fluids. Yet the temporal evolution of SVΔ and ccFTΔ has not been reported in volunteers undergoing a passive leg raise (PLR). METHODS: We recruited clinically-euvolemic, non-fasted, adult, volunteers in a local physiology lab to perform 2 PLR maneuvers, each separated by a 5 minute 'wash-out'. During each PLR, SV was measured by a non-invasive pulse contour analysis device. SV was temporally-synchronized with a wireless, wearable Doppler ultrasound worn over the common carotid artery that continuously measured ccFT. RESULTS: 36 PLR maneuvers were obtained across 19 ambulatory volunteers. 8856 carotid Doppler cardiac cycles were analyzed. The ccFT increased nearly ubiquitously during the PLR and within 40-60 seconds of PLR onset; the rise in SV from the pulse contour device was more gradual. SVΔ by +5% and +10% were both detected by a +7% ccFTΔ with sensitivities, specificities and areas under the receiver operator curve of 59%, 95% and 0.77 (p < 0.001) and 66%, 76% and 0.73 (p < 0.001), respectively. CONCLUSIONS: The ccFTΔ during the PLR in ambulatory volunteers was rapid and sustained. Within the limits of precision for detecting a clinically-significant rise in SV by a non-invasive pulse contour analysis device, simultaneously-acquired ccFT from a wireless, wearable ultrasound system was accurate at detecting 'preload responsiveness'.


Asunto(s)
Pierna , Dispositivos Electrónicos Vestibles , Adulto , Humanos , Volumen Sistólico/fisiología , Pierna/diagnóstico por imagen , Pierna/irrigación sanguínea , Pierna/fisiología , Estudios Prospectivos , Arterias Carótidas/diagnóstico por imagen , Arteria Carótida Común , Ultrasonografía Doppler , Voluntarios , Hemodinámica
16.
Diagnostics (Basel) ; 13(9)2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37174981

RESUMEN

A wireless, wearable Doppler ultrasound offers a new paradigm for linking physiology to resuscitation medicine. To this end, the image analysis of simultaneously-acquired venous and arterial Doppler spectrograms attained by wearable ultrasound represents a new source of hemodynamic data. Previous investigators have reported a direct relationship between the central venous pressure (CVP) and the ratio of the internal jugular-to-common carotid artery diameters. Because Doppler power is directly related to the number of red cell scatterers within a vessel, we hypothesized that (1) the ratio of internal jugular-to-carotid artery Doppler power (V/APOWER) would be a surrogate for the ratio of the vascular areas of these two vessels and (2) the V/APOWER would track the anticipated CVP change during simulated hemorrhage and resuscitation. To illustrate this proof-of-principle, we compared the change in V/APOWER obtained via a wireless, wearable Doppler ultrasound to B-mode ultrasound images during a head-down tilt. Additionally, we elucidated the change in the V/APOWER during simulated hemorrhage and transfusion via lower body negative pressure (LBNP) and release. With these Interesting Images, we show that the Doppler V/APOWER ratio qualitatively tracks anticipated changes in CVP (e.g., cardiac preload) which is promising for both diagnosis and management of hemodynamic unrest.

17.
Crit Care Explor ; 5(5): e0914, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37168690

RESUMEN

Measuring fluid responsiveness is important in the management of critically ill patients, with a 10-15% change in cardiac output typically being used to indicate "fluid responsiveness." Ideally, these changes would be measured noninvasively and peripherally. The aim of this study was to determine how the common carotid artery (CCA) maximum velocity changes with total circulatory flow when confounding factors are mitigated and determine a value for CCA maximum velocity corresponding to a 10% change in total circulatory flow. DESIGN: Prospective observational pilot study. SETTING: Patients undergoing elective, on-pump coronary artery bypass grafting (CABG) surgery. PATIENTS: Fourteen patients were referred for elective coronary artery bypass grafting surgery. INTERVENTIONS: Cardiopulmonary bypass (CPB) pump flow changes during surgery, as chosen by the perfusionist. MEASUREMENTS: A hands-free, wearable Doppler patch was used for CCA velocity measurements with the aim of preventing user errors in ultrasound measurements. Maximum CCA velocity was determined from the spectrogram acquired by the Doppler patch. CPB flow rates were recorded as displayed on the CPB console, and further measured from the peristaltic pulsation frequency visible on the recorded Doppler spectrograms. MAIN RESULTS: Changes in CCA maximum velocity tracked well with changes in CPB flow. On average, a 13.6% change in CCA maximum velocity was found to correspond to a 10% change in CPB flow rate. CONCLUSIONS: Changes in CCA velocity may be a useful surrogate for determining fluid responsiveness when user error can be mitigated.

18.
Crit Care Explor ; 5(5): e0911, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37181538

RESUMEN

Pericardial tamponade can often be diagnosed through clinical findings and echocardiography; however, the diagnosis can be aided by demonstrating the hemodynamic consequences of the effusion. We describe the use of a wearable carotid Doppler device to help diagnose and monitor pericardial tamponade. CASE SUMMARY: A 54-year-old man developed hypotension after an endobronchial biopsy for a lung mass. Echocardiography showed a pericardial effusion with sonographic evidence of tamponade. A wearable carotid Doppler device demonstrated low corrected carotid flow time (CFT) (a surrogate for stroke volume) with significant respiratory variation, supporting the diagnosis of tamponade. The patient underwent pericardiocentesis which revealed purulent pericardial fluid from a mediastinal abscess. After drainage there was increased CFT and reduced respiratory variability in Doppler, surrogates of improved stroke volume. CONCLUSION: A wearable carotid Doppler device is a noninvasive tool that can help determine the hemodynamic impact of a pericardial effusion, and potentially aid in the diagnosis of pericardial tamponade.

19.
Intensive Care Med Exp ; 11(1): 19, 2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-37055637

RESUMEN

BACKGROUND: The venous excess ultrasound (VExUS) score is a multi-organ Doppler approach to assess venous congestion. Despite growing use of VExUS in research and clinical practice, other veins can be visualized to assess for venous hypertension, which may overcome acquisition barriers of the VExUS exam. In this pilot, observational study, we used a wearable Doppler ultrasound to assess the relationship between jugular venous Doppler and the VExUS score under different preload conditions. We hypothesized that jugular Doppler morphology would accurately distinguish preload conditions, that it would most closely relate to the hepatic venous Doppler morphology in the fully supine position and that the VExUS score would be influenced by preload condition. RESULTS: We recruited 15 healthy volunteers with no cardiovascular history. Preload change was achieved using a tilt-table with three positions: supine, fully upright, and 30-degree head-down tilt. In each position, a VExUS score was performed; furthermore, inferior vena collapsibility and sphericity index were calculated. At the same time, jugular venous Doppler was captured by a novel, wireless, wearable ultrasound system. A continuous jugular venous Doppler morphology was 96% accurate for detecting the low preload condition. The jugular venous Doppler morphology was highly correlated with the hepatic vein, but only in the supine position. Gravitational position did not significantly affect the sphericity index or the VExUS score. CONCLUSIONS: The jugular vein Doppler morphology was able to accurately distinguish low from high preload conditions in healthy volunteers. Comparisons between VExUS Doppler morphologies and other veins should occur in the supine position when gravitational pressure gradients are minimized; finally, different preload conditions in healthy subjects did not affect the VExUS score.

20.
J Vis Exp ; (191)2023 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-36744770

RESUMEN

A preload challenge (PC) is a clinical maneuver that, first, increases the cardiac filling (i.e., preload) and, second, calculates the change in cardiac output. Fundamentally, a PC is a bedside approach for testing the Frank-Starling-Sarnoff (i.e., "cardiac function") curve. Normally, this curve has a steep slope such that a small change in the cardiac preload generates a large change in the stroke volume (SV) or cardiac output. However, in various disease states, the slope of this relationship flattens such that increasing the volume into the heart leads to little rise in the SV. In this pathological scenario, additional cardiac preload (e.g., intravenous fluid) is unlikely to be physiologically effective and could lead to harm if organ congestion evolves. Therefore, inferring both the cardiac preload and output is clinically useful as it may guide intravenous (IV) fluid resuscitation. Accordingly, the goal of this protocol is to describe a method for contemporaneously tracking the surrogates of cardiac preload and output using a novel, wireless, wearable ultrasound during a well-validated preload challenge.


Asunto(s)
Corazón , Venas , Gasto Cardíaco/fisiología , Volumen Sistólico/fisiología , Corazón/diagnóstico por imagen , Corazón/fisiología , Ultrasonografía Doppler
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...